When using the description: "Hostile Environment" the code is referring to a working environment where the electrical equipment is normally subjected to movement, events or operating conditions likely to result in damage to the equipment or a reduction in its expected life span. This does not relate to issues or fights between employees. The code often speaks about a hostile work environment. New items do not need to be tested and tagged, in most cases they must have a tag stating that the item is new to service and the date at which it should be tested, we recommend however that even new items be tested as some are found to have faults out of the factory. What requirements apply to hired electrical equipment?Įlectrical equipment that is being hired out, must be inspected each time before leaving the premises and must be inspected, tested and tagged every three months.

australian standard 3760

Practice for electrical testing in construction

#AUSTRALIAN STANDARD 3760 PORTABLE#

They state that all portable electrical items, tools leads and RCD's must be inspected and tested and tagged at least once every three months.Ĭlick here to see the current NSW code of The requirements are outlined in the WorkCover Code of Practice - Electrical practices for construction work. Due to the nature of construction work regular inspection and testing of electrical equipment is warranted and must be carried out. Test and Tag inspections will ensure that at the time of testing the item was safe for use, wear and tear, liquid spills, accidents or damage may make the item unsafe even shortly after testing, as such it is the operators responsibility to have in place a regular maintenance, damage minimisation and inspection program to ensure that each item is safe to use before operating or using the appliance.Īny item found to be dangerous or faulty must have a failed tag applied, showing that the item is dangerous and should not be used, it should be reported or taken to the business owner or safety officer and be immediately removed from service, the item may be repaired or replaced, but must not be used before it has been repaired and re tested.Īre there any special requirements for construction work? Similar to a car rego check, the vehicle if inspected correctly is found to be roadworthy, but usage, damage or accidents may make the car unsafe shortly after. However even with items found to be safe, damage or faults can appear later.

australian standard 3760

Items tested correctly are found to be either safe to use, or unsafe for use. and, where warranted or required, testing of identified electrical equipment.Ĭlick here to see the current (2017) Work

australian standard 3760

After the risk assessment, you can then implement a range of control measures including: To do so you are required to institute and maintain a systematic risk management approach to eliminate or control the risk of electrical hazards. You must therefore manage any safety risks surrounding electrical hazards in accordance with the requirements. The Australian Standards AS/NZS 3760:2010, AS/NZS 3012:2010, Safe Work Australia Code of practice and WorkCover Code of Practice, state that all employers, or self-employed persons, have a duty of care to ensure that employees and visitors to the workplace are safe from injury and risks to health. Why must I inspect, test and maintain my electrical equipment?